S.No | Activity taken upon musteroll | Quantity | Unit Price | Total |
1 | signboard | 1 | 2500 | 2500 |
2 | Earth work in excavation in trenches for foundations and for pipes, cables etc. not exceeding 1.5m in width and for shafts, cesspits and the like not exceeding 10sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5m including getti-Dense or hard soil | 49.556 | 63.9 | 3166.6284 |
3 | Filling foundation and around masonry work with moorum I/c ramming layers and watering. | 16.024 | 131.4 | 2105.5536 |
4 | Providing and laying in foundation, plinth and under floors cement concrete with 40mm nominal size graded stone aggregates (metal) i/c ramming in layers and curing complete excluding cost of form work-C.C. 1:3:6 (1cement, 3sand, 6metal) | 5.526 | 2103.9 | 11626.1514 |
5 | Providing and placing in position RCC for roof, beams, columns column footing lintels chhajjas, balcony, stairs etc, excluding cost of reinforcement & centring but including finishing & curing.-CC 1:1.5:3 (1cement, 1.5sand, 3graded stone aggregate 20 mm nominal size) | 26.208 | 3356 | 87954.048 |
6 | False work for lintels slabs, columns, walls, sills, chhajjas balconies, beams, stair cases or ornamental moulded work, curved surface etc. cast in situ including all lead and lift | 107.4 | 178.2 | 19138.68 |
7 | Class 25 open bhatta or pajawa burnt brick masonry in plinth and foundation.-Cement mortar 1:6 (1cement, 6sand) | 9.269 | 2478.3 | 22971.3627 |
8 | Providing and placing in position tested steel for R.C.C. work including cutting, bending, binding etc. as per drawings and placing in position complete up to floor two level including cost of binding wire and all wastage etc. complete.-Cold twisted / Hot rolled deformed / Thermo mechanicaly treated steel bars | 1965 | 53.9 | 105913.5 |
9 | Providing and fixing steel glazed doors, windows and ventilator of standard Rolled steel sections without horizontal glazing bars, joints mitred and welded with 16X3.15mm lugs 10cm long, embedded in cement concrete block 1:3:6 cement concrete with 20mm gr-Steel doors, windows side hung & ventilator top/ central hung. | 10.8 | 1154.9 | 12472.92 |
10 | Providing and fixing pressed steel door frames manufactured from commercial mild steel sheet of 1.25mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 X 25mm, or base ties of 1.25mm presse-Profile A (single rabate 80mm X 50mm size) | 30.8 | 234.2 | 7213.36 |
11 | 10mm thick cement plaster on fair side of wall in-Cement mortar 1:5 (1cement, 5sand) | 60 | 91.8 | 5508 |
12 | 15mm thick cement plaster on rough side of wall in-Cement mortar 1:4 (1cement, 4sand) | 83.24 | 91.8 | 7641.432 |
13 | Kota stone slab flooring over 20mm thick base of C.M. 1:6 laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including grinding, rubbing & polishing etc. complete. (Area of each stone should not be less than 0.20 S-30 mm thick . | 45.04 | 847.9 | 38189.416 |
14 | Oil bound distemper of approved quality of any shade two coats on new works including priming coat. | 143.24 | 50.1 | 7176.324 |
15 | Painting with enamel paint, brushing, interior to give an even shade I/n cleaning the surface of all dirt dust and other foreign matter on steel and other metal surfaces.-3 coats | 21.6 | 70.7 | 1527.12 |
16 | Spray painting 2 coats excluding priming coat on new steel and other metal surface with enamel paint. | 143.28 | 50.8 | 7278.624 |
17 | Add if Lead is more than 5.00Km-For every 0.5 Kms. Lead beyond 30 Kms. and part there of upto 50 Kms. | 1 | 33636 | 33636 |
18 | contingency | 1 | 16808 | 16808 |
19 | Labour difference in case of old SoR | 1 | 41290 | 41290 |